Authors
Mahmoud I Masoud, Sherif M Dabour, Abd El-Wahab Hassan, Essam M Rashad
Publication date
2015/9/1
Conference
2015 IEEE 10th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)
Pages
327-332
Publisher
IEEE
Description
Five-phase induction motor drive systems have gained much popularity due to the numerous advantages that they offer when compared to their three-phase counterparts. In principle, the supply to five-phase drive system is given from five-phase voltage source inverter (VSI). In this paper, a fault-tolerant control strategy for five-phase VSIs has been suggested. The conventional five-phase inverter consists of only five legs. The proposed strategy forces the faulty phase to connect to the midpoint of the DC-link via the additional dc-bus midpoint inserting Thyristors. The proposed inverter provides tolerance to both short-circuit and open-circuit faults of the switching devices. The performances of the post-fault as well as the normal pre-fault operation are discussed. The fault tolerance of the inverter is verified using vector control of a five-phase induction motor. The complete control scheme is implemented in real-time …
Total citations
2016201720182019202020212022461111
Scholar articles
MI Masoud, SM Dabour, AEW Hassan, EM Rashad - 2015 IEEE 10th International Symposium on …, 2015