Authors
H Ebrahimzadeh, N Tavassoli, MM Amini, Y Fazaeli, H Abedi
Publication date
2010/6/15
Journal
Talanta
Volume
81
Issue
4-5
Pages
1183-1188
Publisher
Elsevier
Description
A simple and rapid method was applied for extraction, preconcentration and determination of trace amounts of gold and palladium in wastewater by using functionalized mesoporous silica. Extraction was investigated on adsorbents prepared by grafting aminopropyl on the surface of MCM-41 and MCM-48 mesoporous silica. The optimum experimental conditions such as pH, flow rates, type and the smallest amount of eluent for elution of Au and Pd, break through volume and the influence of various cationic interferences on the sorption of gold(III) and palladium(II) were evaluated. The extraction efficiency for gold and palladium were greater than 98% and limit of detection (LOD) was lower than 0.06ngmL−1 for gold and 0.1ngmL−1 for palladium on both functionalized MCM-41 and MCM-48 silica. The preconcentration factor was greater than 800 for gold and 400 for palladium and the relative standard deviation …
Total citations
2010201120122013201420152016201720182019202020212022202320241101191914611244423