This paper presents a comparative study of four sizing methods for a stand-alone hybrid generation system integrating renewable energies (photovoltaic panels and wind turbine) and backup and storage system based on battery and hydrogen (fuel cell, electrolyzer and hydrogen storage tank). Two of them perform a technical sizing. In one case, the sizing is based on basic equations, and in the other case, an optimal technical sizing is achieved by using Simulink Design Optimization. The other two methods perform an optimal techno-economical sizing by using the hybrid system optimization software HOMER and HOGA, respectively. These methods have been applied to design a stand-alone hybrid system which supplies the load energy demand during a year. A MATLAB-Simulink model of the hybrid system has been used to simulate the performance of hybrid system designed by each method for the stand …