Authors
Clay S Bell, Timothy Vaughn, Daniel Zimmerle
Publication date
2020
Journal
Elem Sci Anth
Volume
8
Pages
32
Publisher
University of California Press
Description
Twelve next generation emission measurement (NGEM) technologies completed single-blind testing at the Methane Emissions Technology Evaluation Center in 2018. This is the first series of tests to evaluate a wide variety of NGEM solutions including handheld, mobile, and continuous monitoring methods using comparable, repeatable protocols. Results assess performance of detection, localization and quantification, albeit with limited statistical significance due to a low number of tests. Overall, a higher detection rate is observed for handheld and mobile solutions than for continuous monitoring solutions. Compared to when a single emission source is present, a decline in detection rate is observed across all methods when multiple, steady emission sources are present. Localization by handheld and mobile solutions is more accurate than continuous monitoring solutions. These results support the common …