Authors
Pedro Teixeira Lacava, Joao A Carvalho Jr, Amilcar Porto Pimenta, Marco Aurélio Ferreira
Publication date
2006/3/1
Journal
Energy
Volume
31
Issue
4
Pages
528-545
Publisher
Pergamon
Description
The use of oxygen to enrich the combustion air can be an attractive technique to increase capacity of an incinerator originally designed to operate with air. If incinerator parameters such as operation temperature, turbulence level and residence time are fixed for a certain fuel supply rate, it is possible to increase the residue consumption rate using enriched air. This paper presents the thermal analysis for operation with enriched air of an aqueous residue experimental incinerator. The auxiliary fuel was diesel oil. The theoretical results showed that there is a considerable increase in the incineration ratio up to approximately 50% of O2 in the oxidiser. The tendency was confirmed experimentally. Thermal analysis was demonstrated to be an important tool to predict possible incinerator capacity increase.
Total citations
2007200820092010201120122013201420152016201720182019113313111
Scholar articles