Authors
Vickie Wong, Jun Seob Song, Takashi Abe, Robert W Spitz, Yujiro Yamada, Zachary W Bell, Ryo Kataoka, Minsoo Kang, Jeremy P Loenneke
Publication date
2022/2/1
Journal
Biomedical Physics & Engineering Express
Volume
8
Issue
2
Pages
027003
Publisher
IOP Publishing
Description
It is suggested that experience is needed in order to capture valid estimates of muscle size with ultrasound. However, it is unknown whether there is a large degree of skill needed to analyze the images once they are captured.
Objective
To determine if less experienced raters could accurately analyze ultrasound images of the forearm by comparing their estimates with those of a very experienced ultrasonographer (criterion).
Approach
50 muscle thickness images were captured by one experienced ultrasonographer (also Rater 1). Those images were saved and were then measured by four raters with different levels of experience. The rater who captured the images was very experienced (criterion), the second rater was also experienced and provided 5 minutes of instruction for Rater 3 (minimal experience) and Rater 4 (no experience). Test-retest reliability was also determined for Rater 3 and 4.
Main Results
The …