Authors
VHF Brito, GY Kume, MS Quinalia, MA Sachetti, RPB Silva, WA Souza, LCP Silva
Publication date
2016/10/16
Conference
2016 17th International Conference on Harmonics and Quality of Power (ICHQP)
Pages
617-622
Publisher
IEEE
Description
This article analyzes the impact of electronic loads, particularly CRT, LCD and LED televisions, regarding the measurements of reactive power in energy meters of Brazilian Electric Power companies and consequently the influence of those measurements in the reactive surplus Billing (Reactive Energy Excess and Demand Energy Excess). Later, the values obtained from the energy meter are compared to the CPT power components. For the reactive surplus calculation, it is considered not only the reactive power, but also the distortion in the system. It is concluded that the harmonic distortion causes significant interference in measurements of reactive power in energy meters, and that the calculation of reactive power surplus through power factor allows certain inconsistencies in the billing.
Total citations
2017201820192020202120222023121221
Scholar articles
VHF Brito, GY Kume, MS Quinalia, MA Sachetti… - 2016 17th International Conference on Harmonics and …, 2016