Authors
Changyong Zhang, Jinxing Ma, Jingke Song, Calvin He, T David Waite
Publication date
2018/11/21
Journal
Environmental science & technology
Volume
52
Issue
24
Pages
14275-14285
Publisher
American Chemical Society
Description
We have previously described a novel flow-electrode capacitive deionization (FCDI) unit combined with a hydrophobic gas-permeable hollow fiber membrane contactor (designated “CapAmm”) and presented results showing efficient recovery of ammonia from dilute synthetic wastewaters (Zhang et al., Environ. Sci. Technol. Lett. 2018, 5, 43–49). We extend this earlier study here with description of an FCDI system with integrated flat sheet gas permeable membrane with comprehensive assessment of ammonia recovery performance from both dilute and concentrated wastewaters. The integrated CapAmm cell exhibited excellent ammonia removal and recovery efficiencies (up to ∼90% and ∼80% respectively). The energy consumptions for ammonia recovery from low-strength (i.e., domestic) and high-strength (i.e., synthetic urine) wastewaters were 20.4 kWh kg–1 N and 7.8 kWh kg–1 N, respectively, with these …
Total citations
201920202021202220232024112728302624