Authors
Ruurd JA Kuiper, Marijn Van Stralen, Ralph JB Sakkers, Rick HJ Bergmans, Frank Zijlstra, Max A Viergever, Harrie Weinans, Peter R Seevinck
Publication date
2021/8/31
Journal
Physics in Medicine & Biology
Volume
66
Issue
17
Pages
175024
Publisher
IOP Publishing
Description
Purpose
To develop a method that enables computed tomography (CT) to magnetic resonance (MR) image registration of complex deformations typically encountered in rotating joints such as the knee joint.
Methods
We propose a workflow, denoted quaternion interpolated registration (QIR), consisting of three steps, which makes use of prior knowledge of tissue properties to initialise deformable registration. In the first step, the rigid skeletal components were individually registered. Next, the deformation of soft tissue was estimated using a dual quaternion-based interpolation method. In the final step, the registration was fine-tuned with a rigidity-constrained deformable registration step. The method was applied to paired, unregistered CT and MR images of the knee of 92 patients. It was compared to registration using B-Splines (BS) and B-Splines with a rigidity penalty (BSRP). Registration accuracy was evaluated …
Total citations
202220232024151