Clinicians are increasingly utilizing noninvasive serologic tests for the diagnosis and screening of celiac disease (CD). The aim of this study was to conduct a systematic review of the diagnostic performance of serologic tests for the diagnosis and screening of CD. Standard systematic review methodology was used. A literature search was conducted in MEDLINE (1966 to October 2003) and EMBASE (1974 to December 2003) databases. A weighted mean of the sensitivity and specificity along with 95% confidence intervals and summary receiver operating characteristic (ROC) curves were calculated. The pooled specificity of endomyseal antibody (EMA)-monkey esophagus (ME) or EMA-human umbilical cord (HU) was close to 100% in adults and children. The pooled specificity of transglutaminase antibody (tTG)-guinea pig (GP) and tTG-human recombinant (HR) were between 95% and 99%. IgA-EMA-ME …