Performance assessment of HC-290 as a drop-in substitute to HCFC-22 in a window air conditioner S Devotta, AS Padalkar, NK Sane International journal of refrigeration 28 (4), 594-604, 2005 | 200 | 2005 |
Performance and emission analysis of a compression ignition: engine operated on waste fried oil methyl esters JB Hirkude, AS Padalkar Applied Energy 90 (1), 68-72, 2012 | 146 | 2012 |
Performance optimization of CI engine fuelled with waste fried oil methyl ester-diesel blend using response surface methodology JB Hirkude, AS Padalkar Fuel 119, 266-273, 2014 | 126 | 2014 |
Experimental investigation of the effect of compression ratio on performance and emissions of CI engine operated with waste fried oil methyl ester blend J Hirkude, AS Padalkar Fuel processing technology 128, 367-375, 2014 | 95 | 2014 |
Simulated and experimental performance of split packaged air conditioner using refrigerant HC-290 as a substitute for HCFC-22 AS Padalkar, KV Mali, S Devotta Applied Thermal Engineering 62 (1), 277-284, 2014 | 92 | 2014 |
Performance assessment of HCFC-22 window air conditioner retrofitted with R-407C S Devotta, AS Padalkar, NK Sane Applied Thermal Engineering 25 (17-18), 2937-2949, 2005 | 79 | 2005 |
Cinnamomum zeylanicum extract inhibits proinflammatory cytokine TNF∝: in vitro and in vivo studies K Joshi, S Awte, P Bhatnagar, S Walunj, R Gupta, S Joshi, S Sabharwal, ... Research In Pharmaceutical Biotechnology 2 (2), 14-21, 2010 | 61 | 2010 |
Investigations on performance and emission characteristics of diesel engine with biodiesel (jatropha oil) and its blends A Pandhare, A Padalkar Journal of renewable Energy 2013 (1), 163829, 2013 | 48 | 2013 |
Carbon dioxide as natural refrigerant AS Padalkar, AD Kadam International Journal of Applied Engineering Research 1 (2), 261, 2010 | 37 | 2010 |
Comparative assessment of CO2 for window air-conditioners S Devotta, AS Padalkar, SN Joshi, NN Sawant, NK Sane Preliminary Proceedings of the 4th IIR-Gustav Lorentzen Conference on …, 2000 | 21 | 2000 |
Low GWP refrigerants as alternatives to HCFC-22 in room air conditioners S Devotta, AS Padalkar, KV Mali Science and Technology for the Built Environment 22 (8), 1128-1135, 2016 | 17 | 2016 |
Effect of compression ratio on performance of CI engine fuelled with biodiesel from waste fried oil using response surface methodology J Hirkude, A Padalkar, S Shaikh, A Veigas International Journal of Energy Engineering 3 (5), 227-233, 2013 | 16 | 2013 |
Investigations on the effect of waste fried oil methyl ester blends and load on performance and smoke opacity of diesel engine using response surface methodology J Hirkude, A Padalkar, D Vedartham Energy Procedia 54, 606-614, 2014 | 15 | 2014 |
Performance assessment of air conditioners with HC290 AS Padalkar, KV Mali, DD Rajadhyaksha, BJ Wadia, S Devotta 9th IIR Gustav Lorentzen Conference, Sydney, Australia, 2010 | 14 | 2010 |
Prospective of HFC-161 as an alternative to HCFC-22 in air conditioners AS Padalkar, KV Mali, S Devotta Proceedings of the 23rd International Congress of Refrigeration, Prague …, 2011 | 10 | 2011 |
Experimental investigation on the effect of liquid phase and vapor phase separation over performance of falling film evaporator P Anjankar, S Lakade, A Padalkar, S Nichal, Y Devarajan, N Lakshmaiya, ... Environmental Quality Management 33 (1), 61-69, 2023 | 8 | 2023 |
Comparative Study of Transcritical CO2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature AD Kadam, AS Padalkar, VU Walekar International Journal Of Computational Engineering Research Vol. 3 Issue 3, 2013 | 8 | 2013 |
Effect of EGR on the exhaust gas temperature and exhaust opacity in compression ignition engines using Jatropha Oil as fuel AP Pandhare, KC Zende, AS Joglekar, SC Bhave, AS Padalkar Applied mechanics and materials 110, 431-436, 2012 | 8 | 2012 |
Experimental performance assessment of a retrofitted window air conditioner with R-407C S Devotta, AS Padalkar, NK Sane | 8 | 2002 |
EFFECT OF CONTROL OPTIMIZATION OF CO2 TRANSCRITICAL SPLIT AIR CONDITIONER ON THERMAL COMFORT OF OCCUPANTS IN SINGLE ZONE ROOM A Kadam, A Padalkar, S Martínez-Ballester International Journal of Air-Conditioning and Refrigeration 22 (01), 1450006, 2014 | 4 | 2014 |