Maximum principal strain correlates with spinal cord tissue damage in contusion and dislocation injuries in the rat cervical spine CM Russell, AM Choo, W Tetzlaff, TE Chung, TR Oxland Journal of neurotrauma 29 (8), 1574-1585, 2012 | 100 | 2012 |
The effect of window size and lead time on pre-impact fall detection accuracy using support vector machine analysis of waist mounted inertial sensor data O Aziz, CM Russell, EJ Park, SN Robinovitch 2014 36th Annual International Conference of the IEEE Engineering in …, 2014 | 52 | 2014 |
Age-related changes in dynamic compressive properties of trochanteric soft tissues over the hip WJ Choi, CM Russell, CM Tsai, S Arzanpour, SN Robinovitch Journal of biomechanics 48 (4), 695-700, 2015 | 43 | 2015 |
Enhancing clinical measures of postural stability with wearable sensors PM Deshmukh, CM Russell, LE Lucarino, SN Robinovitch 2012 Annual International Conference of the IEEE Engineering in Medicine and …, 2012 | 23 | 2012 |
External hand forces exerted by long-term care staff to push floor-based lifts: Effects of flooring system and resident weight CC Lachance, AMB Korall, CM Russell, F Feldman, SN Robinovitch, ... Human factors 58 (6), 927-943, 2016 | 15 | 2016 |
The Effect of Shoulder Pad Design on Head Impact Severity during Checking. S Virani, CN Russell, ML Bruschetta, KN Hua, BM Potvin, DN Cox, ... Medicine and science in sports and exercise 49 (3), 573-580, 2017 | 14 | 2017 |
Hand forces exerted by long-term care staff when pushing wheelchairs on compliant and non-compliant flooring CC Lachance, AMB Korall, CM Russell, F Feldman, SN Robinovitch, ... Applied Ergonomics 71, 95-101, 2018 | 7 | 2018 |
High-Speed Fluoroscopy Used to Measure Dynamic Spinal Cord Deformation in an In Vivo Rat Model E Lucas, T Whyte, J Liu, CM Russell, W Tetzlaff, PA Cripton Journal of neurotrauma, 2018 | 6 | 2018 |
A nonlinear finite element model of the rat cervical spine: validation and correlation with histological measures of spinal cord injury CM Russell University of British Columbia, 2012 | 5 | 2012 |
Heart Valves: A Fluid Dynamics Perspective C Russell, D Grecov University of British Columbia MECH 410L—Mechanics of Biofluids, Term …, 2008 | 1 | 2008 |
Creation of a finite element model of the rat cervical spine from magnetic resonance images C Russell, TE Chung, T Oxland Journal of Biomechanics, S516, 2008 | 1 | 2008 |
Effects of Compliant Flooring Systems and Resident Weight on Hand Forces When Pushing Floor-Based Lifts and Wheelchairs among Long-Term Care Staff CC Lachance, AMB Korall, CM Russell, SI Johnson, F Feldman, ... Proceedings of the Human Factors and Ergonomics Society Annual Meeting 59 (1 …, 2015 | | 2015 |
Push Forces on Vinyl and Carpet for Conventional Wheeled and Motor-Driven Floor-Based Lifts among Direct Care Staff in Long-Term Care AMB Korall, CC Lachance, CM Russell, SI Johnson, F Feldman, ... Proceedings of the Human Factors and Ergonomics Society Annual Meeting 59 (1 …, 2015 | | 2015 |
A Neutron Radiography Facility for Both Real-Time and Film Applications JA Reuscher, C Russell, Y Crouzet Neutron Radiography (4): Including Radioscopy and Complementary Inspection …, 1993 | | 1993 |
High Speed Radiography Can Be Used to Measure Dynamic Spinal Cord Deformation in an in vivo Rodent Model E Lucas, J Liu, C Russell, W Tetzlaff, P Cripton | | |