Analysis and mitigation of Australian and New Zealand power transformer failures resulting in fires and explosions D Martin, C Beckett, J Brown, S Nielsen IEEE Electrical Insulation Magazine 35 (6), 7-14, 2019 | 25 | 2019 |
Investigations of dielectric monitoring on an energised transformer oil–paper insulation system X Yang, S Nielsen, G Ledwich IET Science, Measurement & Technology 9 (1), 102-112, 2015 | 25 | 2015 |
A systematic review of a statistical vacuum circuit breaker model for condition monitoring S Kam, S Nielsen, G Ledwich IEEE Transactions on Dielectrics and Electrical Insulation 20 (2), 620-627, 2013 | 20 | 2013 |
Frequency domain spectroscopy measurements of oil-paper insulation for energized transformers X Yang, S Nielsen, G Ledwich IEEE Transactions on Dielectrics and Electrical Insulation 24 (3), 1657-1664, 2017 | 19 | 2017 |
Non-linear effects in dielectric response measurments on oil paper insulated power transformers SD Nielsen, GF Ledwich 2015 IEEE 11th International Conference on the Properties and Applications …, 2015 | 7 | 2015 |
A crest factor-based technique for the analysis of polluted insulator leakage current under harmonically distorted supply voltage A Banik, S Nielsen, G Nourbakhsh Electrical Engineering 103, 1823-1836, 2021 | 6 | 2021 |
Development of a switch mode assisted linear amplifier for use as a high fidelity voltage source SD Nielsen, GR Walker, ML Bailey 2015 IEEE 11th International Conference on Power Electronics and Drive …, 2015 | 6 | 2015 |
A Circuit-Breaker restrike diagnostic algorithm using ATP and Wavelet transforms S Kam, S Nielsen, G Ledwich AUPEC 2011, 1-6, 2011 | 5 | 2011 |
Impact of voltage harmonics on condition assessment of polluted insulator through a simulation model A Banik, S Nielsen, G Nourbakhsh 2018 Condition Monitoring and Diagnosis (CMD), 1-5, 2018 | 4 | 2018 |
Equivalent circuit model of polluted insulators with the including effect of supply voltage harmonics A Banik, S Nielsen, G Nourbakhsh 2018 IEEE 2nd International Conference on Dielectrics (ICD), 1-4, 2018 | 4 | 2018 |
Numerical investigation of mechanical and thermal dynamic properties of the industrial transformer HS Liu, L Ma, YT Gu, S Nielsen International Journal of Computational Methods 11 (supp01), 1344012, 2014 | 4 | 2014 |
On-line dielectric response measurements on oil paper insulated transformers SD Nielsen, X Yang, GF Ledwich 2015 IEEE 11th International Conference on the Properties and Applications …, 2015 | 3 | 2015 |
Enhancements to dielectric response measurements of oil-paper insulation for online and offline applications X Yang Queensland University of Technology, 2015 | 3 | 2015 |
The Use of Computer-Aided Partial Discharge Pulse Height Analysis for Diagnostics in Gas Insulated Sub-Stations (GIS) SD Neilsen, JP Reynders 8th International Symposium on High Voltage Engineering, 149-152, 1993 | 3 | 1993 |
Reconstruction of the Transformer Response from On-Line FRA Measurements Performed via Bushing Taps SD Nielsen CMD2018, 2018 | 2 | 2018 |
Experimental investigations of improved dielectric condition monitoring methods on transformer oil-paper insulation system X Yang, S Nielsen, G Ledwich 2014 IEEE 18th International Conference on Dielectric Liquids (ICDL), 1-4, 2014 | 2 | 2014 |
Frequency domain dielectric spectroscopy by using bridge circuit and chirp voltage X Yang, S Nielsen, G Ledwich Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of …, 2015 | 1 | 2015 |
Frequency dielectric influence of imaginary admittance on oil-paper insulation system-a case study X Yang, S Nielsen, G Ledwich Proceedings of the 2013 Australasian Universities Power Engineering …, 2013 | 1 | 2013 |
A study of pre-breakdown discharge activity in SF6 under impulse conditions and the implications for partial discharge measurements SD Nielsen University of the Witwatersrand, 2001 | 1 | 2001 |
The influence of small amounts of N/sub 2/in SF/sub 6/on prebreakdown discharges SD Nielsen, JP Reynders 1999 Eleventh International Symposium on High Voltage Engineering 3, 100-103, 1999 | 1 | 1999 |