Reconfigurable MRI technology for low-SAR imaging of deep brain stimulation at 3T: Application in bilateral leads, fully-implanted systems, and surgically modified lead … E Kazemivalipour, B Keil, A Vali, S Rajan, B Elahi, E Atalar, LL Wald, ... Neuroimage 199, 18-29, 2019 | 64 | 2019 |
Reconfigurable MRI coil technology can substantially reduce RF heating of deep brain stimulation implants: First in-vitro study of RF heating reduction in bilateral DBS leads … L Golestanirad, E Kazemivalipour, B Keil, S Downs, J Kirsch, B Elahi, ... PloS one 14 (8), e0220043, 2019 | 60 | 2019 |
RF heating of deep brain stimulation implants in open‐bore vertical MRI systems: A simulation study with realistic device configurations L Golestanirad, E Kazemivalipour, D Lampman, H Habara, E Atalar, ... Magnetic resonance in medicine 83 (6), 2284-2292, 2020 | 47 | 2020 |
Vertical open‐bore MRI scanners generate significantly less radiofrequency heating around implanted leads: A study of deep brain stimulation implants in 1.2 T OASIS scanners … E Kazemivalipour, B Bhusal, J Vu, S Lin, BT Nguyen, J Kirsch, E Nowac, ... Magnetic resonance in medicine 86 (3), 1560-1572, 2021 | 29 | 2021 |
Patient’s body composition can significantly affect RF power deposition in the tissue around DBS implants: ramifications for lead management strategies and MRI field-shaping … B Bhusal, B Keil, J Rosenow, E Kazemivalipour, L Golestanirad Physics in Medicine & Biology 66 (1), 015008, 2021 | 20 | 2021 |
A patient‐friendly 16‐channel transmit/64‐channel receive coil array for combined head–neck MRI at 7 Tesla MW May, SLJD Hansen, M Mahmutovic, A Scholz, N Kutscha, B Guerin, ... Magnetic resonance in medicine 88 (3), 1419-1433, 2022 | 13 | 2022 |
RF heating of deep brain stimulation implants during MRI in 1.2 T vertical scanners versus 1.5 T horizontal systems: A simulation study with realistic lead configurations E Kazemivalipour, J Vu, S Lin, B Bhusal, BT Nguyen, J Kirsch, B Elahi, ... 2020 42nd Annual International Conference of the IEEE Engineering in …, 2020 | 12 | 2020 |
Effect of field strength on RF power deposition near conductive leads: A simulation study of SAR in DBS lead models during MRI at 1.5 T—10.5 T E Kazemivalipour, A Sadeghi-Tarakameh, B Keil, Y Eryaman, E Atalar, ... PloS one 18 (1), e0280655, 2023 | 11 | 2023 |
Eigenmode analysis of the scattering matrix for the design of MRI transmit array coils E Kazemivalipour, A Sadeghi‐Tarakameh, E Atalar Magnetic resonance in medicine 85 (3), 1727-1741, 2021 | 11 | 2021 |
Accelerating the co-simulation method for the design of transmit array coils for MRI A Sadeghi-Tarakameh, E Kazemivalipour, U Gundogdu, S Erdogan, ... Magnetic Resonance Materials in Physics, Biology and Medicine 34, 165-178, 2021 | 8 | 2021 |
A 128‐channel receive array for cortical brain imaging at 7 T B Gruber, JP Stockmann, A Mareyam, B Keil, B Bilgic, Y Chang, ... Magnetic Resonance in Medicine 90 (6), 2592-2607, 2023 | 7 | 2023 |
A 12-Channel Degenerate Birdcage Body Transmit Array Coil for 1.5T MRI Scanners E Kazemivalipour, A Sadeghi-Tarakameh, U Yilmaz, V Acikel, B Sen, ... Proceedings of the 26th Annual Meeting of ISMRM, 1708, 2018 | 7 | 2018 |
Accelerating the co-simulation method for fast design of transmit array coils: An example study on a degenerate birdcage coil A Sadeghi-Tarakameh, E Kazemivalipour, T Demir, U Gundogdu, E Atalar Proceeding of the 26th Joint Annual Meeting ISMRM-ESMRMB, Paris, France. p 4404, 2018 | 6 | 2018 |
Design of transmit array coils for MRI by minimizing the modal reflection coefficients E Kazemivalipour, A Sadeghi-Tarakameh, E Atalar Proceedings of the 28th Virtual Annual Meeting of ISMRM, 762, 2020 | 5 | 2020 |
Design of a Degenerate Birdcage Radiofrequency Transmit Array Coil for the Magnetic Resonance Imaging Using Equivalent Circuit Model A Sadeghi-Tarakameh, E Kazemivalipour, T Demir, U Gundogdu, E Atalar Proceedings of the 34th Annual Meeting of ESMRMB 30, 300-301, 2017 | 5 | 2017 |
Optimization of the degenerate birdcage transmit array coil for minimum coupling E Kazemivalipour, A Sadeghi-Tarakameh, E Atalar Proceedings of the 27th Annual Meeting of ISMRM, 1604, 2019 | 4 | 2019 |
Design of an 8-channel transmit array coil using the equivalent circuit model of the manufactured structure E Kazemivalipour, A Sadeghi-Tarakameh, U Yilmaz, E Atalar Proceedings of the 28th Virtual Annual Meeting of ISMRM, 758, 2020 | 3 | 2020 |
Design of multi-row multi-channel degenerate birdcage array coil based on minimum total reflection for the single-channel and circularly polarized modes of excitation E Kazemivalipour, A Sadeghi-Tarakameh, U Gundogdu, E Atalar Proceeding of the 27th Joint Annual Meeting ISMRM, 1532, 2019 | 2 | 2019 |
Application of Surgical Lead Management and Reconfigurable Coil Technology to Reduce RF Heating of DBS Implants during MRI at 3T Under Variant Body Compositions B Bhusal, B Elahi, B Keil, J Rosenow, E Kazemivalipour, L Golestanirad bioRxiv, 2020.06. 25.170159, 2020 | 1 | 2020 |
Reconfigurable coil technology significantly reduces the SAR at the tips of bilateral deep brain simulation leads during MRI at 3T: A realistic case study of isolated leads and … E Kazemivalipour, E Atalar, A Vali, B Keil, J Pilitsis, L Golestanirad Proceeding of the 27th Joint Annual Meeting ISMRM, 0727, 2019 | 1 | 2019 |