Follow
J. Jayne Wu
J. Jayne Wu
Electrical Engineering and Computer Science, The University of Tennessee, Knoxville
Verified email at utk.edu - Homepage
Title
Cited by
Cited by
Year
Long-range AC electroosmotic trapping and detection of bioparticles
J Wu, Y Ben, D Battigelli, HC Chang
Industrial & engineering chemistry research 44 (8), 2815-2822, 2005
1992005
Micropumping of biofluids by alternating current electrothermal effects
J Wu, M Lian, K Yang
Applied physics letters 90 (23), 234103-234103-3, 2007
1772007
AC electrothermal manipulation of conductive fluids and particles for lab-chip applications
M Lian, N Islam, J Wu
Nanobiotechnology, IET 1 (3), 36-43, 2007
1632007
Particle detection by electrical impedance spectroscopy with asymmetric-polarization AC electroosmotic trapping
J Wu, Y Ben, HC Chang
Microfluidics and Nanofluidics 1 (2), 161-167, 2005
1552005
Bisphenol A sensors on polyimide fabricated by laser direct writing for onsite river water monitoring at attomolar concentration
C Cheng, S Wang, J Wu, Y Yu, R Li, S Eda, J Chen, G Feng, B Lawrie, ...
ACS applied materials & interfaces 8 (28), 17784-17792, 2016
1282016
AC electrokinetics-enhanced capacitive immunosensor for point-of-care serodiagnosis of infectious diseases
H Cui, Q Yuan, J Wu, A Wadhwa, S Eda
Biosensors and Bioelectronics 51, 437-443, 2014
1142014
Biased AC electro-osmosis for on-chip bioparticle processing
J Wu
Nanotechnology, IEEE Transactions on 5 (2), 84-89, 2006
110*2006
Recent development in chitosan nanocomposites for surface‐based biosensor applications
Y Jiang, J Wu
Electrophoresis, 2019
1012019
Interactions of electrical fields with fluids: laboratory-on-a-chip applications
J Wu
Nanobiotechnology, IET 2 (1), 14-27, 2008
1002008
A highly sensitive and specific capacitive aptasensor for rapid and label-free trace analysis of bisphenol A (BPA) in canned foods
H Mirzajani, C Cheng, J Wu, J Chen, S Eda, EN Aghdam, HB Ghavifekr
Biosensors and Bioelectronics 89 (3), 1059–1067, 2017
942017
Development of an AC electrokinetics-based immunoassay system for on-site serodiagnosis of infectious diseases
X Liu, K Yang, A Wadhwa, S Eda, S Li, J Wu
Sensors and Actuators A: Physical 171 (2), 406-413, 2011
882011
Rapid and sensitive detection of small biomolecule by capacitive sensing and low field AC electrothermal effect
H Cui, C Cheng, X Lin, J Wu, J Chen, S Eda, Q Yuan
Sensors and Actuators B: Chemical 226, 245-253, 2016
852016
Ultrafast micropumping by biased alternating current electrokinetics
M Lian, J Wu
Applied Physics Letters 94, 064101, 2009
852009
Optimization of planar interdigitated microelectrode array for biofluid transport by AC electrothermal effect
Q Yuan, K Yang, J Wu
Microfluidics and nanofluidics 16, 167-178, 2014
802014
Review of non-invasive continuous glucose monitoring based on impedance spectroscopy
J Huang, Y Zhang, J Wu
Sensors and Actuators A: Physical 311, 112103, 2020
792020
An AC electrokinetic impedance immunosensor for rapid detection of tuberculosis
H Cui, S Li, Q Yuan, A Wadhwa, S Eda, M Chambers, R Ashford, H Jiang, ...
Analyst 138 (23), 7188-7196, 2013
792013
Highly sensitive and specific on-site detection of serum cocaine by a low cost aptasensor
R Oueslati, C Cheng, J Wu, J Chen
Biosensors and Bioelectronics 108, 103-108, 2018
672018
Capacitive aptasensor coupled with microfluidic enrichment for real-time detection of trace SARS-CoV-2 nucleocapsid protein
H Qi, Z Hu, Z Yang, J Zhang, JJ Wu, C Cheng, C Wang, L Zheng
Analytical chemistry 94 (6), 2812-2819, 2022
652022
Design and characterization of a passive, disposable wireless AC-electroosmotic lab-on-a-film for particle and fluid manipulation
H Mirzajani, C Cheng, J Wu, CS Ivanoff, EN Aghdam, HB Ghavifekr
Sensors and Actuators B: Chemical 235, 330-342, 2016
642016
Rapid, highly sensitive detection of Gram-negative bacteria with lipopolysaccharide based disposable aptasensor
J Zhang, R Oueslati, C Cheng, L Zhao, J Chen, R Almeida, J Wu
Biosensors and Bioelectronics 112, 48-53, 2018
632018
The system can't perform the operation now. Try again later.
Articles 1–20