Follow
Andrea Giovanni Cutti
Andrea Giovanni Cutti
Applied Research Manager - INAIL Prosthetic Center
Verified email at inail.it
Title
Cited by
Cited by
Year
Literature review on needs of upper limb prosthesis users
F Cordella, AL Ciancio, R Sacchetti, A Davalli, AG Cutti, E Guglielmelli, ...
Frontiers in neuroscience 10, 209, 2016
7992016
Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors
AG Cutti, A Giovanardi, L Rocchi, A Davalli, R Sacchetti
Medical & biological engineering & computing 46 (2), 169-178, 2008
3772008
‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors
AG Cutti, A Ferrari, P Garofalo, M Raggi, A Cappello, A Ferrari
Medical & biological engineering & computing 48 (1), 17, 2010
2452010
First in vivo assessment of “Outwalk”: a novel protocol for clinical gait analysis based on inertial and magnetic sensors
A Ferrari, AG Cutti, P Garofalo, M Raggi, M Heijboer, A Cappello, ...
Medical & biological engineering & computing 48 (1), 1, 2010
2212010
A framework for the definition of standardized protocols for measuring upper-extremity kinematics
A Kontaxis, AG Cutti, GR Johnson, HEJ Veeger
Clinical Biomechanics 24 (3), 246-253, 2009
1762009
A new formulation of the coefficient of multiple correlation to assess the similarity of waveforms measured synchronously by different motion analysis protocols
A Ferrari, AG Cutti, A Cappello
Gait & posture 31 (4), 540-542, 2010
1642010
Gait symmetry and regularity in transfemoral amputees assessed by trunk accelerations
A Tura, M Raggi, L Rocchi, AG Cutti, L Chiari
Journal of neuroengineering and rehabilitation 7 (1), 4, 2010
1582010
Soft tissue artefact assessment in humeral axial rotation
AG Cutti, G Paolini, M Troncossi, A Cappello, A Davalli
Gait & Posture 21 (3), 341-349, 2005
1552005
Functionally interpretable local coordinate systems for the upper extremity using inertial & magnetic measurement systems
WHK De Vries, HEJ Veeger, AG Cutti, C Baten, FCT Van Der Helm
Journal of biomechanics 43 (10), 1983-1988, 2010
1232010
Gait analysis in children with cerebral palsy via inertial and magnetic sensors
JC van den Noort, A Ferrari, AG Cutti, JG Becher, J Harlaar
Medical & biological engineering & computing 51 (4), 377-386, 2013
1022013
SIAMOC position paper on gait analysis in clinical practice: General requirements, methods and appropriateness. Results of an Italian consensus conference
MG Benedetti, E Beghi, A De Tanti, A Cappozzo, N Basaglia, AG Cutti, ...
Gait & posture 58, 252-260, 2017
1012017
The reliability of upper limb kinematics in children with hemiplegic cerebral palsy
E Jaspers, H Feys, H Bruyninckx, A Cutti, J Harlaar, G Molenaers, ...
Gait & posture 33 (4), 568-575, 2011
1002011
Impact of Michelangelo prosthetic hand: Findings from a crossover longitudinal study
M Luchetti, AG Cutti, G Verni, R Sacchetti, N Rossi
Journal of Rehabilitation Research & Development 52 (5), 605-620, 2015
942015
Methodological factors affecting joint moments estimation in clinical gait analysis: a systematic review
V Camomilla, A Cereatti, AG Cutti, S Fantozzi, R Stagni, G Vannozzi
Biomedical engineering online 16 (1), 106, 2017
882017
Inter-operator reliability and prediction bands of a novel protocol to measure the coordinated movements of shoulder-girdle and humerus in clinical settings
P Garofalo, AG Cutti, MV Filippi, S Cavazza, A Ferrari, A Cappello, ...
Medical & biological engineering & computing 47 (5), 475-486, 2009
822009
Ambulatory measurement of the scapulohumeral rhythm: intra-and inter-operator agreement of a protocol based on inertial and magnetic sensors
I Parel, AG Cutti, G Fiumana, G Porcellini, G Verni, AP Accardo
Gait & posture 35 (4), 636-640, 2012
732012
Treatment of the partial hand amputation: an engineering perspective
I Imbinto, C Peccia, M Controzzi, AG Cutti, A Davalli, R Sacchetti, ...
IEEE reviews in biomedical engineering 9, 32-48, 2016
632016
In vivo validation of a new technique that compensates for soft tissue artefact in the upper-arm: preliminary results
AG Cutti, A Cappello, A Davalli
Clinical Biomechanics 21, S13-S19, 2006
612006
Energy storing and return prosthetic feet improve step length symmetry while preserving margins of stability in persons with transtibial amputation
H Houdijk, D Wezenberg, L Hak, AG Cutti
Journal of neuroengineering and rehabilitation 15 (1), 76, 2018
572018
A simple test to assess the static and dynamic accuracy of an inertial sensors system for human movement analysis
AG Cutti, A Giovanardi, L Rocchi, A Davalli
Engineering in Medicine and Biology Society, 2006. EMBS'06. 28th Annual …, 2006
572006
The system can't perform the operation now. Try again later.
Articles 1–20