Monte Carlo modelling of a‐Si EPID response: the effect of spectral variations with field size and position L Parent, J Seco, PM Evans, A Fielding, DR Dance Medical physics 33 (12), 4527-4540, 2006 | 104 | 2006 |
VESUVIO: a novel instrument for performing spectroscopic studies in condensed matter with eV neutrons at the ISIS facility R Senesi, C Andreani, Z Bowden, D Colognesi, E Degiorgi, AL Fielding, ... Physica B: Condensed Matter 276, 200-201, 2000 | 90 | 2000 |
Multiple scattering in deep inelastic neutron scattering: Monte Carlo simulations and experiments at the ISIS eVS inverse geometry spectrometer J Mayers, AL Fielding, R Senesi Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2002 | 81 | 2002 |
Amorphous silicon EPID calibration for dosimetric applications: comparison of a method based on Monte Carlo prediction of response with existing techniques L Parent, AL Fielding, DR Dance, J Seco, PM Evans Physics in Medicine & Biology 52 (12), 3351, 2007 | 66 | 2007 |
Evaluation of two methods of predicting MLC leaf positions using EPID measurements L Parent, J Seco, PM Evans, DR Dance, A Fielding Medical physics 33 (9), 3174-3182, 2006 | 62 | 2006 |
Assessment of cone beam CT registration for prostate radiation therapy: Fiducial marker and soft tissue methods T Deegan, R Owen, T Holt, A Fielding, J Biggs, M Parfitt, A Coates, ... Journal of medical imaging and radiation oncology 59 (1), 91-98, 2015 | 54 | 2015 |
Calibration of the electron volt spectrometer, a deep inelastic neutron scattering spectrometer at the ISIS pulsed neutron spallation source AL Fielding, J Mayers Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2002 | 51 | 2002 |
Verification of patient position and delivery of IMRT by electronic portal imaging AL Fielding, PM Evans, CH Clark Radiotherapy and oncology 73 (3), 339-347, 2004 | 39 | 2004 |
Radiotherapy treatment verification using radiological thickness measured with an amorphous silicon electronic portal imaging device: Monte Carlo simulation and experiment T Kairn, D Cassidy, PM Sandford, AL Fielding Physics in Medicine & Biology 53 (14), 3903, 2008 | 38 | 2008 |
Utilising the virtual environment for radiotherapy training system to support undergraduate teaching of IMRT, VMAT, DCAT treatment planning, and QA concepts C Chamunyonga, J Burbery, P Caldwell, P Rutledge, A Fielding, S Crowe Journal of medical imaging and radiation sciences 49 (1), 31-38, 2018 | 36 | 2018 |
Developing a contextualised blended learning framework to enhance medical physics student learning and engagement I Czaplinski, AL Fielding Physica Medica 72, 22-29, 2020 | 35 | 2020 |
Modeling a complex micro‐multileaf collimator using the standard BEAMnrc distribution T Kairn, J Kenny, SB Crowe, AL Fielding, RD Franich, PN Johnston, ... Medical Physics 37 (4), 1761-1767, 2010 | 35 | 2010 |
Measurement of anisotropies of the kinetic energy and anharmonicity in pyrolytic graphite by neutron Compton scattering AL Fielding, DN Timms, J Mayers Europhysics Letters 44 (2), 255, 1998 | 34 | 1998 |
The use of electronic portal imaging to verify patient position during intensity-modulated radiotherapy delivered by the dynamic MLC technique AL Fielding, PM Evans, CH Clark International Journal of Radiation Oncology* Biology* Physics 54 (4), 1225-1234, 2002 | 33 | 2002 |
Radiobiological model comparison of 3D conformal radiotherapy and IMRT plans for the treatment of prostate cancer P Deb, A Fielding Australasian Physics & Engineering Sciences in Medicine 32, 51-61, 2009 | 28 | 2009 |
Intraobserver variability: should we worry? P Bridge, A Fielding, P Rowntree, A Pullar Journal of medical imaging and radiation sciences 47 (3), 217-220, 2016 | 27 | 2016 |
Final-state effects in neutron Compton scattering measurements on zirconium deuteride and beryllium AL Fielding, DN Timms, AC Evans, J Mayers Journal of Physics: Condensed Matter 8 (38), 7205, 1996 | 23 | 1996 |
The development of a Monte Carlo system to verify radiotherapy treatment dose calculations S Crowe, T Kairn, AL Fielding 10th Biennial ESTRO, 2009 | 19 | 2009 |
Kinetic energy of He atoms in liquid mixtures R Senesi, C Andreani, AL Fielding, J Mayers, WG Stirling Physical Review B 68 (21), 214522, 2003 | 18 | 2003 |
The effect of beam arrangements and the impact of non‐coplanar beams on the treatment planning of stereotactic ablative radiation therapy for early stage lung cancer R Fitzgerald, R Owen, T Barry, C Hargrave, D Pryor, A Bernard, ... Journal of Medical Radiation Sciences 63 (1), 31-40, 2016 | 17 | 2016 |