U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice FJ Beekman, F van der Have, B Vastenhouw, AJA van der Linden, ... Journal of Nuclear Medicine 46 (7), 1194-1200, 2005 | 399 | 2005 |
U-SPECT-II: an ultra-high-resolution device for molecular small-animal imaging F Van Der Have, B Vastenhouw, RM Ramakers, W Branderhorst, JO Krah, ... Journal of Nuclear Medicine 50 (4), 599-605, 2009 | 363 | 2009 |
A novel, SiPM-array-based, monolithic scintillator detector for PET DR Schaart, HT van Dam, S Seifert, R Vinke, P Dendooven, H Löhner, ... Physics in Medicine & Biology 54 (11), 3501, 2009 | 346 | 2009 |
The pinhole: gateway to ultra-high-resolution three-dimensional radionuclide imaging F Beekman, F van der Have European journal of nuclear medicine and molecular imaging 34, 151-161, 2007 | 286 | 2007 |
Design and simulation of a high-resolution stationary SPECT system for small animals FJ Beekman, B Vastenhouw Physics in Medicine & Biology 49 (19), 4579, 2004 | 278 | 2004 |
LaBr3: Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time DR Schaart, S Seifert, R Vinke, HT van Dam, P Dendooven, H Löhner, ... Physics in Medicine & Biology 55 (7), N179, 2010 | 270 | 2010 |
Modelling the physics in the iterative reconstruction for transmission computed tomography J Nuyts, B De Man, JA Fessler, W Zbijewski, FJ Beekman Physics in Medicine & Biology 58 (12), R63, 2013 | 268 | 2013 |
Accelerated iterative transmission CT reconstruction using an ordered subsets convex algorithm C Kamphuis, FJ Beekman IEEE Transactions on Medical Imaging 17 (6), 1101-1105, 1998 | 265 | 1998 |
Review and current status of SPECT scatter correction BF Hutton, I Buvat, FJ Beekman Physics in Medicine & Biology 56 (14), R85, 2011 | 252 | 2011 |
Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation FJ Beekman, HWAM de Jong, S van Geloven IEEE transactions on medical imaging 21 (8), 867-877, 2002 | 238 | 2002 |
Performance evaluation of A-SPECT: a high resolution desktop pinhole SPECT system for imaging small animals DP McElroy, LR MacDonald, FJ Beekman, Y Wang, BE Patt, JS Iwanczyk, ... IEEE Transactions on Nuclear Science 49 (5), 2139-2147, 2002 | 195 | 2002 |
Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT W Zbijewski, FJ Beekman IEEE transactions on medical imaging 25 (7), 817-827, 2006 | 192 | 2006 |
Accelerated simulation of cone beam X-ray scatter projections AP Colijn, FJ Beekman IEEE Transactions on medical imaging 23 (5), 584-590, 2004 | 176 | 2004 |
A clinical perspective of accelerated statistical reconstruction BF Hutton, HM Hudson, FJ Beekman European journal of nuclear medicine 24, 797-808, 1997 | 170 | 1997 |
Real-time prompt gamma monitoring in spot-scanning proton therapy using imaging through a knife-edge-shaped slit V Bom, L Joulaeizadeh, F Beekman Physics in Medicine & Biology 57 (2), 297, 2011 | 168 | 2011 |
Ordered subset reconstruction for x-ray CT FJ Beekman, C Kamphuis Physics in medicine & biology 46 (7), 1835, 2001 | 161 | 2001 |
Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction MC Maas, DR Schaart, DJJ van der Laan, P Bruyndonckx, C Lemaître, ... Physics in Medicine & Biology 54 (7), 1893, 2009 | 150 | 2009 |
Scatter compensation methods in 3D iterative SPECT reconstruction: a simulation study FJ Beekman, C Kamphuis, EC Frey Physics in Medicine & Biology 42 (8), 1619, 1997 | 147 | 1997 |
Towards in vivo nuclear microscopy: iodine-125 imaging in mice using micro-pinholes FJ Beekman, DP McElroy, F Berger, SS Gambhir, EJ Hoffman, SR Cherry European journal of nuclear medicine and molecular imaging 29, 933-938, 2002 | 146 | 2002 |
Submillimeter total-body murine imaging with U-SPECT-I B Vastenhouw, F Beekman Journal of Nuclear Medicine 48 (3), 487-493, 2007 | 145 | 2007 |