Seuraa
Freek Beekman
Freek Beekman
Hoogleraar Biomedical Imaging
Vahvistettu sähköpostiosoite verkkotunnuksessa tudelft.nl - Kotisivu
Nimike
Viittaukset
Viittaukset
Vuosi
U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice
FJ Beekman, F van der Have, B Vastenhouw, AJA van der Linden, ...
Journal of Nuclear Medicine 46 (7), 1194-1200, 2005
3992005
U-SPECT-II: an ultra-high-resolution device for molecular small-animal imaging
F Van Der Have, B Vastenhouw, RM Ramakers, W Branderhorst, JO Krah, ...
Journal of Nuclear Medicine 50 (4), 599-605, 2009
3632009
A novel, SiPM-array-based, monolithic scintillator detector for PET
DR Schaart, HT van Dam, S Seifert, R Vinke, P Dendooven, H Löhner, ...
Physics in Medicine & Biology 54 (11), 3501, 2009
3462009
The pinhole: gateway to ultra-high-resolution three-dimensional radionuclide imaging
F Beekman, F van der Have
European journal of nuclear medicine and molecular imaging 34, 151-161, 2007
2862007
Design and simulation of a high-resolution stationary SPECT system for small animals
FJ Beekman, B Vastenhouw
Physics in Medicine & Biology 49 (19), 4579, 2004
2782004
LaBr3: Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time
DR Schaart, S Seifert, R Vinke, HT van Dam, P Dendooven, H Löhner, ...
Physics in Medicine & Biology 55 (7), N179, 2010
2702010
Modelling the physics in the iterative reconstruction for transmission computed tomography
J Nuyts, B De Man, JA Fessler, W Zbijewski, FJ Beekman
Physics in Medicine & Biology 58 (12), R63, 2013
2682013
Accelerated iterative transmission CT reconstruction using an ordered subsets convex algorithm
C Kamphuis, FJ Beekman
IEEE Transactions on Medical Imaging 17 (6), 1101-1105, 1998
2651998
Review and current status of SPECT scatter correction
BF Hutton, I Buvat, FJ Beekman
Physics in Medicine & Biology 56 (14), R85, 2011
2522011
Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation
FJ Beekman, HWAM de Jong, S van Geloven
IEEE transactions on medical imaging 21 (8), 867-877, 2002
2382002
Performance evaluation of A-SPECT: a high resolution desktop pinhole SPECT system for imaging small animals
DP McElroy, LR MacDonald, FJ Beekman, Y Wang, BE Patt, JS Iwanczyk, ...
IEEE Transactions on Nuclear Science 49 (5), 2139-2147, 2002
1952002
Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT
W Zbijewski, FJ Beekman
IEEE transactions on medical imaging 25 (7), 817-827, 2006
1922006
Accelerated simulation of cone beam X-ray scatter projections
AP Colijn, FJ Beekman
IEEE Transactions on medical imaging 23 (5), 584-590, 2004
1762004
A clinical perspective of accelerated statistical reconstruction
BF Hutton, HM Hudson, FJ Beekman
European journal of nuclear medicine 24, 797-808, 1997
1701997
Real-time prompt gamma monitoring in spot-scanning proton therapy using imaging through a knife-edge-shaped slit
V Bom, L Joulaeizadeh, F Beekman
Physics in Medicine & Biology 57 (2), 297, 2011
1682011
Ordered subset reconstruction for x-ray CT
FJ Beekman, C Kamphuis
Physics in medicine & biology 46 (7), 1835, 2001
1612001
Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction
MC Maas, DR Schaart, DJJ van der Laan, P Bruyndonckx, C Lemaître, ...
Physics in Medicine & Biology 54 (7), 1893, 2009
1502009
Scatter compensation methods in 3D iterative SPECT reconstruction: a simulation study
FJ Beekman, C Kamphuis, EC Frey
Physics in Medicine & Biology 42 (8), 1619, 1997
1471997
Towards in vivo nuclear microscopy: iodine-125 imaging in mice using micro-pinholes
FJ Beekman, DP McElroy, F Berger, SS Gambhir, EJ Hoffman, SR Cherry
European journal of nuclear medicine and molecular imaging 29, 933-938, 2002
1462002
Submillimeter total-body murine imaging with U-SPECT-I
B Vastenhouw, F Beekman
Journal of Nuclear Medicine 48 (3), 487-493, 2007
1452007
Järjestelmä ei voi suorittaa toimenpidettä nyt. Yritä myöhemmin uudelleen.
Artikkelit 1–20